Special Cable

NAN brand cable...... Specializing in the development and production of environmentally friendly wire and cable enterprises. In recent years, the company has developed a metal sheathed mineral insulated cable (YTTWY), mineral flexible fire-resistant cable (BTTRZ), charging pile cables, submarine cables and other cables...

YTTW/YTTWY Rated voltage 750V and below metal sheath inorganic mineral insulated cable product introduction

DATE:2017-3-29 16:24:26 HITS:0

Rated voltage 750V and below various types of buildings  fire fighting system;
large shopping malls,  hospitals, airports, petroleum, chemical, nuclear power, aerospace, national  defense engineering, satellite launch, central control center and other  important places;

BBTRZ rated voltage 0.6/1kV mineral insulated flexible cable refractory product introduction

DATE:2017-3-29 16:04:44 HITS:0

Rated voltage 0.6/1V and below the fire protection requirements of the higher level of all types of buildings fire system;Large shopping malls, hospitals, subways, airports, docks, aerospace, defense engineering, satellite launch, central control center and other important places;
Oil, nuclear power station, metallurgy, chemical industry, mine, kiln and other dangerous, harsh, high temperature environment

Rated voltage 8.7kV/15kV XLPE insulated steel tape(steel wire) armored PE (PVC) sheathed power cable product introduction

DATE:2017-3-28 22:36:15 HITS:0

1 Rated power-frequency  voltage U0/U: 3.6/6kv~8.7/15kV.
2 Max. admissible  operating temperature of the conductor:90℃. Max. Short-circuit temperature of conductor shall not exceed  250C(5s maximum duration).
3 The ambient temperature  under installation should not below 0 Deg C.

Rated voltage 26kV/35kV XLPE insulated steel tape(steel wire) armored PE (PVC) sheathed power cable product introduction

DATE:2017-3-28 21:42:11 HITS:0

1 Rated power-frequency  voltage U0/U: 3.6/6kv~26/35kv.
2 Max. admissible  operating temperature of the conductor:90℃. Max. Short-circuit temperature of conductor shall not exceed  2500C(5s maximum duration).
3 The ambient temperature  under installation should not below 0 Deg C.

Guangzhou Nanyang cable Co. Ltd.

No. 19 Yongfeng Road, Yonghe District, Guangzhou economic and Technological Development Zone, Guangdong, China

© 2016 - 2017 NANYANG CABLE All Rights Reserved.

CONTACT:

National Sales:+86-13922732011

FoShan Region:+86-18680032231

TEL:+86-020-32206876

FAX:+86-020-32208011

E-MAIL:2685119216@qq.com gznycable@126.com

网站备案:

粤ICP备16116334号-3